Southfield, Michigan residents, Randazzo Heating, Cooling and Electrical welcomes you! We are the name to trust for furnace and air conditioning repair, maintenance and installation. Our team also provides exceptional work on electrical systems and water heaters.
As HVAC specialists serving Southfield, Michigan and the Metro Detroit area, we know what it takes to keep your home comfortable. Since 1988, we’ve served the residents of Oakland County. Our headquarters is located just down the road in Macomb County, on Quadrate Dr. We also offer friendly customer service to many of your neighbors in communities like Bloomfield Hills, Warren, Sterling Heights, and Troy.
System malfunctions and breakdowns don’t always happen during normal business hours. We provide 24-hour emergency services for this very reason. Our insured technicians are just a phone call away and can arrive promptly with the tools and experience to get the job done, no matter what time you need us.
Read on to learn more about our skills and services as HVAC specialists in Southfield, Michigan.
Expert HVAC & Indoor Air Quality Services in Southfield
You need your HVAC units to run at peak performance in order to stay cool during the summer months and warm during the winter.
Randazzo’s services are custom tailored to respond to any issue you may face throughout the changing Michigan seasons.
Talk to us about your heating and cooling needs. We have decades of experience fixing HVAC systems in Southfield with comprehensive furnace and air conditioning repair services.
Our insured technicians can also help you prolong the life of your units with maintenance, cleaning, inspection and other services for your heating and cooling systems.
There comes a time when even the best units wear out and require replacement. Luckily, Randazzo has some of the best products on the market. We are proud to be Michigan’s largest award-winning Lennox Premier Dealer, installing state-of-the-art air conditioning systems, furnaces and other great HVAC products, including those that can improve your indoor air quality.
Water Heater Repair & Replacement Services
Your hot water heater needs to function at peak performance in order to provide for your home. You use this necessity to do the dishes, take a hot shower or launder your clothes.
If your unit breaks down and stops giving you the hot water you need, get in touch with Randazzo. Our team will provide a quick and efficient hot water heater repair for your Southfield, MI, residence. We also provide routine maintenance and installation services, recirculation systems and heat pump repair. Our team has experience working on conventional, tankless, hybrid and many other types of hot water heaters.
Experienced Electricians in Southfield, MI
Keep the power on all the time. Randazzo is an experienced electrician in Southfield, MI, with a team of technicians led by our master electrician. From meeting appliance requirements with circuit or panel upgrades, to the installation of standby generators, we have you covered with many electrical services. Our team also has comprehensive repair and maintenance experience to keep your existing units in shape.
Contact Randazzo for Heating and Cooling in Southfield
“Go with the name you know” for HVAC, water heater and electrical services in Southfield. We’ve helped your neighbors for over three decades and look forward to assisting you. Get in touch with us today by calling 586-336-1111 (toll free) for more information. You can also contact us to receive an estimate, free of charge.
Recent Jobs and Reviews in Southfield, MI
Job Locations and Reviews
Completed full HVAC system installation including a 110,000 BTU gas furnace and 4-ton air conditioning unit. Installed new flue liner, ran dedicated electrical circuit for system operation, and secured all required mechanical and electrical permits prior to installation. System tested and operational upon completion.
Responded to callback for 6-year-old furnace located in basement with no heat complaint. Unit was running but not delivering warm air to living spaces. Performed diagnostic testing and measured supply air temperatures at multiple registers throughout home to verify inadequate heat output. Identified issue related to previous service visit and completed necessary repairs under parts warranty coverage. Verified proper airflow and temperature rise across heat exchanger, confirmed all safety controls operating within specifications, and tested system through complete heating cycle to ensure restored functionality.
Successfully installed a 50-gallon Bradford White automatic storage water heater in the basement utility area. Completed all plumbing connections using copper piping with brass fittings, including installation of a red-handled ball valve for shutoff control. All connections were properly secured and tested for leaks to ensure safe operation.
Completed annual cooling maintenance on residential air conditioning condenser unit. Performed comprehensive system inspection, measured refrigerant pressures and temperatures using digital manifold gauges, verified proper superheat and subcooling values, and documented unit condition. Unit shows significant exterior deterioration with corroded protective grilles and damaged screening, though system is currently operational with acceptable refrigerant charge levels.
Completed annual fall heating maintenance on residential HVAC system. Performed comprehensive inspection of outdoor condenser unit, including cleaning of exterior panels, verification of fan operation, and securing of all hardware components. Unit found in satisfactory operating condition with routine maintenance tasks completed per manufacturer specifications.
Performed on-site assessment for new Kohler whole home generator installation. Evaluated existing electrical panel configuration and available utility connections in mechanical space to determine equipment placement, transfer switch location, and required electrical infrastructure upgrades. Documented current electrical system layout and identified routing pathways for generator connection to main distribution panel.
Performed complimentary white glove air conditioning maintenance inspection on 5-ton split system. Upon accessing the indoor evaporator coil assembly, found significant accumulation of dirt, dust, and debris throughout the finned heat exchanger surfaces, with contamination unevenly distributed across the coil face. Documented equipment condition with photographs showing heavy soiling that could restrict airflow and reduce system efficiency if left unaddressed. Verified electrical connections and wiring at coil assembly were secure and properly terminated.
Completed HVAC estimate for full system replacement in residential property. Assessed existing furnace, water heater, and ductwork configuration in basement mechanical room. Identified basement subpanel as appropriate electrical connection point for new air conditioning installation. Documented current equipment layout and clearance areas, noting stored items requiring temporary relocation during installation. Provided comprehensive system evaluation including electrical infrastructure, existing heating equipment, and available space for new AC components.
Responded to water leak complaint originating from hot water tank. Upon inspection, identified a 40-gallon natural gas water heater manufactured in July 2015 showing signs of deterioration and active leaking. Documented unit specifications including model and serial number for replacement purposes. Observed water accumulation in drain pan beneath HVAC system, indicating ongoing leak condition. Photographed water heater data plate and affected drain pan area with visible water damage and staining. Advised customer that leak indicates end of life for existing water heater and recommended replacement. Customer acknowledged condition and elected to proceed with necessary repairs.
Completed scheduled Air Care Maintenance on outdoor condensing unit. Performed comprehensive system inspection, checked refrigerant levels, cleaned condenser coils, verified electrical connections, and tested unit operation to ensure optimal cooling performance for the upcoming season.
Conducted site assessment for installation of second mini-split system in server room of commercial facility. Evaluated electrical panel capacity and confirmed adequate breaker space available for additional unit. Documented existing conditions including ceiling infrastructure with drop tile system and wall-mounted equipment, noting moisture damage present on ceiling tiles that may require attention during installation to ensure proper drainage routing for new condensate lines.
Conducted on-site evaluation for air conditioning system replacement estimate. Inspected existing mechanical equipment located in unfinished basement area, including current furnace and water heater configuration, ductwork infrastructure, and available space for new AC installation. Documented existing conditions through photographs of indoor mechanical room showing exposed framing, concrete flooring, and overhead duct routing, as well as exterior areas where outdoor condensing unit would be positioned. Assessed electrical service capacity, drainage requirements, refrigerant line routing options, and integration points with existing HVAC infrastructure to provide comprehensive replacement system recommendations.
Provided estimate for new air conditioning system installation in basement location where no existing A/C unit is currently present. Assessed basement utility area with existing air handler and mechanical equipment to determine optimal placement and integration requirements for new cooling system, including evaluation of available electrical service, gas meter accessibility, and ductwork connections to support complete A/C installation.
Completed annual maintenance tune-up on residential Goodman forced air furnace and air conditioning system. Performed comprehensive inspection of gas furnace including heat exchanger, burner assembly, blower motor, and all electrical connections; verified proper operation of all components with no issues identified. Conducted AC system tune-up with both heating and cooling systems found to be operating within normal parameters at time of service.
Completed annual cooling maintenance on residential air conditioning system. Performed comprehensive inspection of outdoor condensing unit, checked refrigerant levels using manifold gauges, verified proper operation of condenser fan motor and compressor, cleaned condenser coils, and confirmed electrical connections were secure. Unit operating within normal parameters at time of service completion.
Completed annual cooling maintenance on residential outdoor condensing unit. Performed comprehensive system inspection, cleaned condenser coils, checked refrigerant levels, tested electrical connections, and verified proper operation of all components. Unit operating within manufacturer specifications with no issues identified.
Completed annual HVAC maintenance on residential heating and cooling system. Performed comprehensive inspection of gas furnace, verified proper burner operation with blue flame combustion, tested gas valve functionality, and examined all electrical connections and wiring. Inspected draft inducer motor assembly, PVC intake and exhaust venting, and internal components for wear or damage. Replaced air filters as needed and ensured all safety controls were operating within manufacturer specifications. System tested and left in proper working condition.
Completed HVAC system estimate for medium-sized residential heating system replacement in basement location. Evaluated existing natural gas furnace installation serving 1200-2000 square foot area, assessed current ductwork configuration, PVC venting infrastructure, and electrical connections. Provided comprehensive replacement quote for new gas-fired heating unit with proper sizing specifications based on existing mechanical room layout and utility connections.
Provided comprehensive estimate for replacement of 30+ year old furnace and air conditioning system located on main level. Current natural gas furnace and AC unit are operational but have exceeded their expected service life. Assessed existing equipment configuration, electrical panel capacity, ductwork connections, and utility closet installation space to determine replacement specifications and compatibility requirements.
Completed annual cooling maintenance on outdoor condensing unit. Performed comprehensive system inspection including visual assessment of cabinet condition, coil cleanliness, and overall equipment operation. Unit showed significant exterior weathering with heavy black streaking and staining on metal panels, indicating accumulated dirt, oxidation, and biological growth. Documented equipment condition with detailed photographs for service records. Heat exchanger coils exhibited dust and debris buildup typical of outdoor HVAC equipment. Verified fan grille assembly and mounting hardware secure. System operational at time of service completion.