Randazzo Heating, Cooling, and Electrical welcomes you! We are your Fraser heating and cooling provider, serving the residents of Macomb County and surrounding areas in Metro Detroit.
Located on Qaudrate Dr., we are a part of your community and have already served many of your neighbors for more than 30 years.
When you need quality HVAC services, water heater repair or electrical upgrades, count on our experienced team to provide you with the skills, products and customer service needed for an exemplary experience.
If you are in Fraser, St. Clair Shores, Sterling Heights, or any other nearby community, don’t hesitate to get in touch with us for a repair, replacement or maintenance call for your system.
See why so many families trust us with their HVAC, water heater, and electrical needs by reading on.
Fraser Air Conditioning and Furnace Services
When it comes to heating and cooling, it’s best to enlist the services of a professional who knows what it takes to stay comfortable and improve efficiencies.
Randazzo leverages more than three decades of experience in the HVAC industry to keep your Fraser air conditioning and furnace units functioning properly.
Talk to us about our heating and cooling services. We provide a wide variety of heating and cooling repairs and have experience fixing numerous unit types from top manufacturers.
Our team can also help you prevent costly breakdowns and improve the efficiency of your air conditioning and furnace systems with our heating and cooling preventative maintenance programs.
Even the best systems will eventually need to be replaced. If it’s time for an upgrade, we have the products and the installation skills for the job. We are Michigan’s largest award-winning Lennox Premier Dealer, offering a full line of state-of-the-art air conditioning systems, furnaces, and more that can improve your indoor air quality.
Your Fraser heating and cooling team is here for you no matter what you need.
Fraser Hot Water Heater Repair
Is your hot water heater not working correctly? It can be frustrating when you need to do the dishes, take a shower, or finish loads of laundry but don’t have the resources you need. Randazzo provides comprehensive hot water heater inspection, repair and installation services and we can diagnose any problem you may have. From conventional to tankless units, our insured technicians have worked with numerous hot water heater types and will be more than happy to restore your hot water with a repair or by replacing your unit.
Fraser Electrician
Randazzo can help you harness the power you need for new appliances and keep the lights on when conventional power sources fail. Our team of skilled electricians, led by our master electrician, are here to help. We install panel and circuit upgrades, as well as standby generators with quality service and the right tools for every job. Your Fraser electrical team will keep you out of the dark – guaranteed.
Contact Randazzo Today
Randazzo has always believed in serving communities with quality craftsmanship, efficiency, and customer service that goes above and beyond. Since 1988, we have lived by these values and continue to do so today.
Talk with us about your needs and schedule your next service call for HVAC, water heater repair, or electrical upgrades. Call 586-336-1111 (toll free) today for more information, and contact us to request a free estimate.
Recent Jobs and Reviews in Fraser, MI
Job Locations and Reviews
Responded to callback for outdoor AC unit not turning off following previous service visit where wiring was replaced. Upon arrival, inspected condensate drain system and float switch assembly, which was found to be preventing proper unit shutdown. Cleaned debris from outdoor unit top surface, verified fan operation, and tested condensate drainage components to ensure proper cycling. System tested successfully with unit now shutting off as designed.
Completed comprehensive AC tune-up and maintenance on two central air conditioning units (4-year-old and 2-year-old systems). Performed thorough inspection of both systems, cleaned dirty air filters showing significant dust and debris accumulation, verified thermostat operation displaying proper cooling mode functionality at 67°F setpoint, and confirmed both units were operating within normal parameters. All components inspected and serviced to ensure optimal performance for the cooling season.
Conducted comprehensive assessment of existing HVAC system for full replacement estimate. Evaluated 20+ year old furnace and air conditioning equipment located in basement utility area, documenting current system configuration including ductwork distribution, venting arrangements, and equipment placement. Photographed existing furnace unit with black vent pipe installation and adjacent AC components to support replacement specifications and sizing requirements for new equipment installation.
Completed annual heating maintenance and tune-up on 10-year-old furnace system as part of membership service. Performed comprehensive inspection, tested all operational components, verified proper airflow and combustion efficiency, and checked refrigerant pressures using manifold gauges. System found operating within normal parameters with no issues identified; all safety controls functioning properly and unit ready for heating season.
Responded to no-cooling call on 4-year-old central air conditioning system. Indoor unit blower was operating but outdoor condensing unit failed to run. Upon inspection, discovered failed dual-run capacitor preventing compressor and condenser fan motor operation. Replaced defective capacitor with OEM-equivalent component, restored power, and verified proper system operation with outdoor unit running and achieving temperature setpoint.
Completed comprehensive air conditioning maintenance inspection on residential condensing unit. Performed system diagnostics using digital manifold gauges, recording operating pressures, superheat, and subcooling values to verify proper refrigerant charge and system performance. Unit operating within normal parameters with no deficiencies noted during inspection.
Performed scheduled preventive maintenance on residential air conditioning system. Verified system pressures and temperatures using digital manifold gauges, confirming proper refrigerant charge and operational parameters across high and low side readings. Inspected outdoor condenser unit, copper refrigerant lines, and all mechanical components for proper operation and wear.
Completed full HVAC system installation including a 70,000 BTU gas furnace (model ML196UH070XE36BK-01) and 2-ton air conditioning unit with rear discharge configuration. Installation included ductwork with galvanized metal transitions, furnace liner, PVC condensate drainage system, and complete electrical reconnection. All required mechanical and electrical permits were obtained prior to installation, and system was fully commissioned and operational upon completion.
Completed comprehensive maintenance service on 11-year-old Lennox Industries central air conditioning system. Addressed customer concerns regarding system noise while confirming unit maintained proper heating and cooling functionality. Performed routine maintenance inspection, documenting exterior unit condition including significant weathering on condenser panels, biological growth on base components, and deteriorated concrete pad with moss accumulation. Renewed annual maintenance plan to ensure continued system performance and longevity.
Completed annual cooling maintenance on residential air conditioning system. Performed comprehensive inspection of outdoor condenser unit, verified proper operation of fan motor and compressor, checked refrigerant levels, and cleaned debris from around unit base and stone paver area. Documented equipment condition with photos showing normal weathering and standard operating status for outdoor installation.
Conducted on-site evaluation of existing residential air conditioning system for replacement estimate. Assessed current HVAC installation in basement utility area, including air handler, ductwork configuration, humidifier integration, and associated plumbing connections. Documented existing equipment condition and spatial requirements through detailed photography to develop comprehensive replacement proposal for aging cooling system.
Completed full HVAC system installation including 90,000 BTU furnace and 3-ton air conditioning unit with left-side configuration. Installed humidifier, established all necessary PVC condensate drainage lines, reconnected gas supply lines, and routed metallic ductwork and electrical connections. Obtained mechanical and electrical permits prior to installation, with all work performed to code in basement utility area.
Conducted on-site assessment for complete HVAC system replacement of approximately 40-year-old furnace and air conditioning equipment. Evaluated existing air handler unit and ductwork configuration in basement mechanical room, documented current equipment specifications and installation layout. Prepared comprehensive replacement quote for new furnace and air conditioner system to address aging equipment concerns and improve system efficiency.
Completed violation repair callback on 3-ton AC system in basement of 1950s-built residence. Installed SAFE-T-SWITCH secondary float switch in auxiliary condensate drain line per code requirements, connecting to existing PVC drain piping and copper line configuration. Verified proper operation of safety switch and confirmed wiring connections to control board terminal block, ensuring system shutdown protection in the event of drain line blockage.
Provided comprehensive estimate for complete HVAC system replacement including furnace and air conditioning unit for 41-year-old equipment currently located in basement. Existing system remains operational but has exceeded typical service life expectancy. Assessment included evaluation of outdoor condensing unit positioned in side yard area and basement-installed furnace with associated ductwork and electrical components.
Completed annual preventative maintenance on residential outdoor air conditioning condenser unit. Performed comprehensive system inspection, verified proper operation of all components, and documented equipment condition with photographic records. Unit found to be operating within normal parameters with no immediate service needs identified.
Completed annual furnace maintenance on residential HVAC air handler system installed in basement utility room. Performed comprehensive tune-up including inspection of all mechanical components, electrical connections, and associated PVC condensate drainage lines. Verified proper operation of furnace unit, examined ductwork connections, refrigerant lines, and manufacturer specifications. All systems tested and found operating within normal parameters. Documentation photos captured for service records.
Completed installation of 70,000 BTU furnace and 2.5 ton air conditioning system in rear yard location with humidifier and reconnection of existing components. All necessary mechanical and electrical permits were obtained prior to installation. Condenser unit was positioned on rubber pad over concrete base; however, follow-up service is required to remove wooden support under pad and fill void beneath left side of condenser with pea stone to ensure proper leveling and drainage.
Completed annual heating maintenance on 10-year-old furnace system. Performed comprehensive tune-up including inspection of heat exchanger, burner assembly, gas valve, blower motor, and all electrical connections. Verified proper operation of all safety controls, checked combustion air intake and exhaust venting system, and confirmed unit is functioning within manufacturer specifications. System operating properly with no deficiencies noted.
Completed annual heating and cooling maintenance service on residential HVAC system. Performed comprehensive inspection of gas furnace, including examination of control board, gas valve assembly, inducer motor, blower components, and all electrical connections. Verified proper operation of safety controls and flame sensor. Inspected heat exchanger for cracks or deterioration. Tested ignition system and confirmed proper burner operation and flame characteristics. Conducted full maintenance on outdoor condensing unit, including cleaning of condenser coils and removal of debris from unit exterior and surrounding area. Inspected fan motor operation and verified proper amperage draw. Checked refrigerant pressures and confirmed system is operating within manufacturer specifications. Examined electrical connections at contactor and capacitor. Verified proper compressor operation and assessed overall unit performance. Both heating and cooling systems tested and found to be operating efficien