Clinton Township Service Overview
- Local Priority: Serving the Hall Road (M-59) corridor and neighborhoods near Partridge Creek every single day.
- Certified Expertise: Expert technicians who understand the distinct technical needs of Clinton Township’s varied home ages.
- Efficiency Focus: Specialized in high-efficiency systems that manage the specific climate demands of Macomb County.
“I was contacted by Randazzo for a maintenance check on my furnace that they installed. The service technician was professional and friendly. He answered my questions and even changed my furnace filter. Overall, I didn’t expect the call but it was much appreciated.”
Electrical Upgrades & Backup Power
Power demand in Clinton Township has increased significantly, especially in homes near the Partridge Creek area. Between modern appliances and EV chargers, older electrical panels often fall behind. We provide reliable solutions that keep your home running without interruption.
- Generator Installation: Authorized Generac and Kohler services.
- Panel Upgrades: Modernizing systems for today’s high-demand appliances.
- EV Charger Installation: Professional setups for home charging stations.
- Surge Protection: Whole-home protection against local grid spikes.
Furnace Repair & Heating System Work
Heating systems in neighborhoods tied to Chippewa Valley Schools take a heavy beating during Michigan winters. We often find that older furnaces lose efficiency over time, leading to higher energy bills and uneven heat. We correct these issues so your system runs reliably when you need it most.
- Heating Repair: Fast diagnostics for furnaces and heat pumps.
- System Replacement: Energy-efficient upgrades for older township homes.
- Seasonal Maintenance: Precision tuning to prevent winter breakdowns.
“Randazzo is my first choice for install and service. 25 years in my home and they have been there for me all along. Very professional and knowledgeable. On time and had my system running perfectly.”
Air Conditioning & Water Systems
Cooling in Clinton Township often comes down to airflow. Larger homes and finished basements require properly balanced systems to stay comfortable. Additionally, we specialize in sump pump services to protect your finished lower levels from the flooding risks common to our area.
- AC Troubleshooting: Solving uneven cooling and airflow issues.
- Sump Pump Service: Protecting basements with reliable backup systems.
- Water Heaters: Repairs and high-efficiency tankless upgrades.
Solving Clinton Township Home Issues
Problem: Residents near Hall Road often experience electrical panel tripping due to the high power demand of modern home technology.
Solution: We perform comprehensive panel upgrades and dedicated circuit installations to ensure your home can handle modern loads safely.
Problem: Homeowners frequently report that their furnace runs constantly but fails to provide even warmth in every room.
Solution: We recalibrate your heating system and seal ductwork to optimize airflow and lower your monthly energy expenses.
Problem: Finished basements in Clinton Township are at high risk of damage if the primary sump pump fails during a heavy rainstorm.
Solution: We install professional-grade battery backup pumps that automatically take over to keep your basement dry, even when the power is out.
“Everything went great and all is working as it should be. I am really impressed with the service and professionalism.”
Why Clinton Township Chooses Randazzo
We prioritize reliability over quick fixes, ensuring your home systems run without disruption.
- Local Experts: We understand the specific climate and home patterns across Macomb County.
- Fast Response: Our teams are already in Clinton Township and along Hall Road every day.
- Comprehensive Care: One trusted company for HVAC, electrical, and plumbing needs.
- Transparent Fixes: Technicians who explain the problem and the solution clearly.
Do you provide service near The Mall at Partridge Creek?
Can you help with an electrical panel upgrade?
Are your technicians certified for furnace repairs?
Recent Jobs and Reviews in Clinton Township, MI
Job Locations and Reviews
Responded to no hot water complaint and performed diagnostic evaluation on American Water Heater Company 50-gallon natural gas water heater, model PVG6250T60NV. Documented unit specifications and current condition through photographic documentation of manufacturer's data plate showing 50,000 BTU rating and 160 PSI working pressure capacity.
Completed comprehensive Air Care maintenance inspection on residential HVAC system including both heating and cooling components. Performed standard preventative maintenance procedures on outdoor condenser unit, inspecting operational condition, cleaning accessible surfaces, and verifying proper system function. Unit showed normal weathering and surface accumulation consistent with outdoor installation; all components operating within acceptable parameters upon completion of maintenance protocol.
Responded to no heat call on eight-year-old forced air furnace reported to be tripping with a small leak but still providing heat. Performed comprehensive system diagnostics including combustion analysis, which revealed acceptable readings: 10.6% O2, 6 PPM CO, 102% efficiency on natural gas high-efficiency unit with stack temperature at 105.9°F. Inspected flexible ductwork and system components, verified temperature differentials at 25°F across system, and confirmed unit operational status. Identified minor leak condition requiring monitoring; system remains functional with satisfactory combustion parameters.
Conducted on-site evaluation for new mini split installation in residential bedrooms to provide air conditioning prior to home sale. Assessed bedroom dimensions (18x12 with 7'5" ceiling height) and existing conditions, including wall-mounted unit location above furnishings. Evaluated exterior placement options for condenser unit along brick wall near covered porch area, considering accessibility for installation and service access.
Conducted on-site evaluation of non-functional Bryant Plus 90 high-efficiency gas furnace located in basement. Unit is 15+ years old and has reached end of serviceable life. Provided comprehensive estimate for complete furnace replacement system including new high-efficiency unit, venting modifications, ductwork connections, and all necessary components to restore residential heating capability.
Responded to no hot water complaint on tanked water heater system. Upon inspection, discovered the flue vent pipe had become disconnected from the water heater draft hood assembly. The galvanized vent pipe separation created an unsafe venting condition and prevented proper draft, causing the unit's safety controls to shut down burner operation. Reconnected the flue vent pipe to the draft hood, ensuring proper alignment and secure fit. Verified all venting components were properly seated and sealed. Tested water heater operation after repair, confirmed burner ignition, proper draft through the flue system, and restoration of hot water production. Unit returned to normal operating condition with safe venting restored.
Completed full system estimate for replacement of 16-year-old furnace and outdoor air conditioning condenser unit. Assessed existing equipment in basement utility area and exterior installation against brick wall, documenting current system configuration including ductwork and electrical connections. Provided customer with multiple replacement options including both high-efficiency and standard-efficiency equipment packages to meet requested timeline for replacement within the next couple weeks.
Performed follow-up service visit to generator unit to install cold weather kit. Inspected engine compartment and verified proper access to coolant system components, including engine block heater connections and associated hoses. Documented current configuration of Kohler generator system, including oil cooler assembly, shutdown controls, and electrical safety systems prior to scheduled cold weather kit installation. Unit requires return visit to complete cold weather kit installation at no charge.
# HVAC Service Report Responded to no-cooling complaint on 5-year-old air conditioning system. Upon arrival, performed system diagnostics using digital manifold gauges to assess refrigerant pressures and temperatures. High-side pressure reading showed 234 psig with elevated temperature of 335°F, indicating potential system issues. Inspected electrical disconnect box at outdoor unit, verifying proper fuse installation and electrical connections. Confirmed 25-amp fusing was intact and all wire terminations at bus bars and terminal blocks were secure. Checked power supply connections including line voltage wiring. Connected refrigerant manifold with service hoses to system ports for comprehensive pressure and temperature analysis. Monitored superheat and subcooling values to determine refrigerant charge status and system performance. Documented readings on digital gauge display for accurate diagnostics. Performed visual inspection of outdoor unit components and electrical supply syste
Completed scheduled maintenance on outdoor air conditioning condenser unit, including inspection of all accessible components, cleaning of condenser coils and fan assembly, and verification of proper system operation. Replaced air filter and evaporator pad as part of routine preventative maintenance to ensure optimal cooling efficiency and system longevity.
Completed on-site assessment for furnace replacement estimate on 32-year-old unit currently located in basement mechanical room. Existing furnace remains operational but has exceeded typical service life expectancy. Documented current installation configuration including ductwork connections, venting system, electrical supply, and gas line routing to provide accurate replacement specifications and ensure proper equipment sizing for the residence.
Performed annual cooling maintenance on residential air conditioning system. Inspected outdoor condensing unit and found moderate accumulation of dirt and debris on condenser coil fins, which can restrict airflow and reduce system efficiency. Documented existing condition with photos showing dust buildup on coil surfaces and environmental debris around unit base. Observed weathering on unit exterior casing and condensate drain line. All major components operational at time of inspection. System started and running as expected following maintenance procedures.
Provided estimate for replacement of non-functioning standard tank water heater in basement utility room. Assessed existing white cylindrical water heater with copper pipe connections, gas control valve, and supply lines requiring replacement. Customer requires consultation with contractor's authority due to boiler system integration considerations before proceeding with installation.
Completed annual cooling maintenance on residential split system. Inspected air filter condition, verified proper airflow through evaporator coil, and performed electrical diagnostics on outdoor condenser unit using digital clamp meter to measure amperage draw and confirm compressor operation within manufacturer specifications. All components operating normally with no issues identified.
Responded to urgent service call for Lochinvar tanked water heater experiencing leaks from top and side connections with complete loss of hot water supply. Upon inspection, identified active water leakage causing moisture damage on basement concrete floor. Performed diagnostic evaluation of tank integrity, inlet/outlet connections, temperature and pressure relief valve, and all associated plumbing connections to determine source of failure and assess whether repair or replacement was most appropriate solution.
Performed comprehensive assessment of non-functional 12-year-old air conditioning system requiring full replacement. Documented existing equipment specifications including refrigerant evaporator coil and heat pump components, photographed manufacturer labels with technical ratings and serial numbers, and inspected electrical panel configuration to determine replacement requirements and ensure proper system compatibility for quote preparation.
Completed annual cooling maintenance on residential air conditioning system. Performed system diagnostics using refrigerant manifold gauges to verify proper refrigerant pressures, superheat, and subcooling levels. Replaced air filters and evaporator pads, and performed spot cleaning of condenser unit exterior and coils to ensure optimal airflow and system efficiency.
Responded to service call for 20-year-old outdoor A/C unit not cooling properly. Upon arrival, found significant debris accumulation around condenser base including leaves, grass clippings, and organic material restricting airflow. Observed exposed and disorganized electrical wiring at contactor with multiple wire loops present. Cleared all debris from around unit perimeter and base. Inspected condenser coils, electrical connections, and condensate drain line. Unit located on concrete pad against brick exterior wall with adequate clearance from surrounding vegetation. Performed diagnostic evaluation and discussed findings with homeowner regarding system age and performance concerns. No warranties apply to parts or labor on this legacy equipment.
Completed annual cooling maintenance on Lennox outdoor condensing unit. Performed routine inspection of equipment exterior, verified unit positioning on equipment pad, and assessed overall system condition. Filter and evaporative cooler pad replacement required and noted for service completion.
Completed ComfortGuard Maintenance Package on residential air conditioning system. Performed standard maintenance procedures including filter replacement as requested, conducted visual inspection of outdoor condenser unit which revealed extensive exterior corrosion, rust damage, and deteriorating cabinet panels with compromised protective coating. Unit remains operational but exterior casing shows significant weathering and material degradation that may require future attention to prevent further deterioration of internal components.