Residents of Washington, Michigan, welcome to Randazzo! We’re so happy you’ve found your way to us, so that we can be of service. We provide exceptional HVAC maintenance, repair and installation services to keep your home comfortable, year-round.
Trust the Washington, MI heating and cooling experts at Randazzo to meet your air conditioning and heating needs. Our expert, trained, and certified technicians are right around the corner whenever you need us. With over 30 years’ experience serving Washington, Michigan, and the surrounding areas, it’s likely many of your neighbors are already familiar with our team. Here, we detail how we can help assist with repairing your electric, water heater and heating and cooling systems in Washington, MI.
Heating and Cooling, Washington MI: Maintenance, Repair and Installation
We’re known for serving the community with HVAC repair in Washington, but we also spend much of our time ensuring your continued comfort with maintenance checks, and upgrading residences with new HVAC installations.
Air Conditioning Services, Washington
Our air conditioning technicians will work hard to keep your trusted AC running to the best of its ability with maintenance checks, and can stop by for repairs whenever they’re required. In need of a new AC system? We’re here to help you keep cool no matter what, with air conditioning services in Washington.
Heating Services, Washington
When the cold Michigan winter approaches, our first thought turns to the comfort of our local families in Washington and beyond. We’re here to ensure you stay warm through the long winter months, with furnace cleanings, inspections, maintenance, repairs and installations. We even offer 24-hour emergency heating services.
Furnace and AC Installation
If you’d like to upgrade to a new air conditioner or furnace, Randazzo has you covered. As the largest certified Lennox dealer located near Washington Township, we can offer you high quality equipment with a great warranty, at the lowest cost around. We strive to be the best heating and cooling company near the Washington Township area!
Water Heater Repair Washington, MI
Your hot water heater is essential, and we don’t want any of our neighbors to go without. Our water heater repair services are affordable and professional. With many parts stored in our trucks, chances are, we may be able to complete your repair there and then.
Electrician, Washington MI
Our exceptional electricians are here to serve you, Washington families. Whether you need us to install an automatic standby generator or complete lighting, fan or circuit repairs, our trusted team is here for you. Led by out master electrician, our team can offer you efficient, affordable repairs and peace of mind.
Local, Family Owned Heating and Cooling Contractor
At Randazzo, we believe in the personal touch. Located just outside of Washington Township, Michigan, we’re a family-owned furnace and air conditioner service company. Everyone here at Randazzo, from the President to the Janitor, lives and works nearby. For quality service you can trust, go with the name you know: Randazzo.
Request Your Free Quote
We’re proud to be a local HVAC company, offering home services for your heating and air conditioning, water heater and electric. When you choose to work with Randazzo, you receive exceptional customer service from our skilled technicians.
Our headquarters, on Quadrate Drive in Macomb, is just a 15-minute drive from Washington, Michigan. We’re the friendly neighbor you can count on to make your comfort our priority.
Contact us today to request your free quote, and enjoy the peace of mind that comes with working with a fully insured, certified, professional and local team.
Recent Jobs and Reviews in Washington, MI
Job Locations and Reviews
Conducted on-site estimate for tankless natural gas water heater installation in basement utility room. Assessed existing Rheem Performance conventional tank water heater and evaluated current natural gas infrastructure to determine feasibility of connecting new tankless unit alongside recently installed natural gas grill. Photographed existing water heater configuration, including flexible gas connectors, venting arrangement, and surrounding utility connections. Inspected electrical panel capacity and breaker configuration to verify adequate power supply for tankless unit's electronic ignition and control systems. Evaluated existing gas line sizing, routing, and capacity to support simultaneous operation of proposed tankless water heater and new outdoor grill. Assessed basement mechanical room layout, clearance requirements, and optimal placement for tankless installation considering combustion air requirements, venting pathways, and accessibility for maintenance. Documented current p
Completed full system estimate for 3,000 square foot two-story home with full basement. Assessed existing 21-year-old Bryant PLUS 90t furnace at end of life expectancy, documented electrical panel configuration and current HVAC installation with photographs. Provided comprehensive replacement options with focus on mid-grade equipment solutions for immediate system replacement needs.
Responded to no-heat emergency call for 22-year-old furnace that had shut down due to burning smell. Upon arrival, inspected the yellow-cased furnace unit and associated ductwork system in basement utility area. Documented existing equipment condition through photographs showing the aged heating system with gray ductwork, exposed electrical components, and surrounding mechanical infrastructure. Given the unit's age beyond typical service life, safety concerns from the reported burning odor, and urgent heating needs with cold weather approaching, provided replacement estimate as requested. System remains offline pending customer decision on replacement due to safety concerns associated with the burning smell at shutdown.
Completed full HVAC system installation including a 90,000 BTU gas furnace and 3.5-ton air conditioning unit with rear discharge configuration. Installed all required ductwork, PVC venting, humidifier integration, and electrical connections in basement utility area. System was evacuated to proper vacuum levels (335 microns verified), refrigerant lines connected, and all mechanical and electrical permits obtained for code compliance.
Completed annual maintenance on residential air conditioning condenser unit. Performed comprehensive system inspection, cleaned condenser coils, checked refrigerant levels, tested electrical connections, and verified proper operation of all components. Unit is operating within manufacturer specifications and ready for the cooling season.
Completed annual preventive maintenance on outdoor air conditioning condenser unit. Performed comprehensive system inspection, cleaned condenser coils, checked refrigerant levels, tested electrical connections, and verified proper operation of all components. Unit is operating within normal parameters and ready for the cooling season.
Completed annual preventative maintenance on Lennox outdoor condensing unit. Performed comprehensive system inspection, tested electrical components with diagnostic meters, verified proper operation of compressor and condenser fan motor, cleaned condenser coils, and confirmed unit is operating within manufacturer specifications for the cooling season.
Completed estimate for furnace replacement in residential basement mechanical room. Documented existing Bryant Plus 90 high-efficiency furnace, associated ductwork, venting system, and surrounding utility infrastructure including water heater and electrical panel to provide accurate replacement specifications and equipment requirements.
Completed annual cooling maintenance on Goodman residential condenser unit. Performed comprehensive system inspection, verified proper operation of compressor and condenser fan motor, checked electrical connections and disconnect box, and confirmed adequate refrigerant levels. Unit operating within normal parameters with no deficiencies noted at time of service.
Completed annual cooling maintenance on residential outdoor condenser unit. Performed comprehensive system inspection, photographed equipment condition noting significant exterior paint deterioration and cabinet wear. Documented debris accumulation around unit base including leaves, dirt, and vegetation growth between paver joints. Verified electrical disconnect accessibility and proper safety cone placement during service. Unit operational upon completion of maintenance protocol.
Completed annual cooling maintenance on residential air conditioning system. Performed comprehensive inspection of outdoor condensing unit, verified proper operation of all components, checked refrigerant lines and electrical connections, and tested system performance with diagnostic equipment. No air filters required at this time, and residential annual contract was processed during the visit.
Responded to callback regarding incomplete AC installation from November. Upon arrival, no previous technician notes were available to indicate outstanding work. Documented site conditions with photos for record. Unable to determine specific incomplete items without further system inspection or customer clarification of concerns.
Responded to service call for furnace leaking water in closet location. Upon inspection, discovered significant water damage and staining around flue pipe penetration through ceiling, indicating condensate leak from high-efficiency furnace exhaust system. Identified improper sealing and potential blockage in condensate drainage system causing water to back up and leak around vent pipe assembly. Documented existing water damage to drywall and ceiling materials surrounding the metal flue pipe and mounting flange. Equipment is under both parts and labor warranty coverage.
Completed installation of 90,000 BTU furnace unit in basement mechanical room, including all necessary mechanical and electrical connections. Obtained required permits and performed full system reconnection with proper venting and ductwork integration. Unit tested and operational upon completion.
Completed annual cooling maintenance on residential air conditioning system. Condenser unit showed significant accumulation of dirt, dust, and environmental debris on aluminum fins and coil surfaces. Performed thorough cleaning of condenser coils to restore proper airflow and heat transfer efficiency. Inspected fan motor assembly, electrical connections, and refrigerant lines. Unit rescheduled for preventive maintenance visits in fall and spring seasons to maintain optimal system performance.
Provided comprehensive estimate for furnace and air conditioning system replacement in basement installation. Current furnace is non-operational while existing air conditioning unit remains functional. Assessed aging HVAC equipment including beige furnace cabinet with exposed internal components, blower motor assembly, and associated ductwork and refrigerant lines. Documented existing system configuration including PVC venting, copper refrigerant tubing, electrical connections, and plenum arrangement. Recommended replacement of both heating and cooling units to ensure brand compatibility and system efficiency. Photographed current equipment conditions showing internal furnace components, air handler assembly, ductwork connections, and mechanical room layout to support estimate preparation.
Completed annual cooling maintenance on residential HVAC system, inspecting air handler unit, ductwork, electrical connections, and condensate drainage lines. All components operating within normal parameters with no filter replacement required at this time.
Completed annual preventative maintenance on residential outdoor condensing unit. Performed comprehensive system inspection, verified proper operation of all components including fan motor and compressor, checked refrigerant lines for integrity, and documented unit condition with photos showing equipment in functional state with minor outdoor weathering consistent with normal exposure.
# HVAC Maintenance Summary Completed annual cooling maintenance on residential air conditioning system. Performed comprehensive inspection of outdoor condenser unit, including cleaning of coil fins which showed moderate dirt and debris accumulation. Replaced air filters as needed and addressed routine maintenance requirements to ensure optimal system performance for the upcoming cooling season. # Detailed Work Performed Arrived on site and performed scheduled annual cooling maintenance on residential split system air conditioner. Conducted thorough visual inspection of outdoor condenser unit, noting accumulation of dirt, debris, and organic material on condenser coil surfaces and surrounding area. Removed top fan grille assembly to access internal components. Inspected fan motor, blades, and electrical connections for proper operation and signs of wear. Verified fan motor operation and checked for unusual noise or vibration. Cleaned condenser coil fins using appropriate cleaning me
# HVAC Maintenance - ACM Completed Performed comprehensive annual cooling maintenance on residential HVAC system. Replaced furnace filters and humidifier pad as part of scheduled maintenance protocol. Conducted thorough inspection of outdoor condensing unit, measuring capacitor performance with digital multimeter to verify proper electrical function and confirm readings within manufacturer specifications. Evaluated indoor air handler unit, utilizing clamp meter to measure amperage draw on blower motor and verify electrical consumption within normal operating parameters. Inspected all electrical connections, control wiring, and component operation. Verified proper airflow and system cycling. All components tested and found operating within acceptable ranges. System left in proper working condition with all access panels secured.