Residents of Washington, Michigan, welcome to Randazzo! We’re so happy you’ve found your way to us, so that we can be of service. We provide exceptional HVAC maintenance, repair and installation services to keep your home comfortable, year-round.
Trust the Washington, MI heating and cooling experts at Randazzo to meet your air conditioning and heating needs. Our expert, trained, and certified technicians are right around the corner whenever you need us. With over 30 years’ experience serving Washington, Michigan, and the surrounding areas, it’s likely many of your neighbors are already familiar with our team. Here, we detail how we can help assist with repairing your electric, water heater and heating and cooling systems in Washington, MI.
Heating and Cooling, Washington MI: Maintenance, Repair and Installation
We’re known for serving the community with HVAC repair in Washington, but we also spend much of our time ensuring your continued comfort with maintenance checks, and upgrading residences with new HVAC installations.
Air Conditioning Services, Washington
Our air conditioning technicians will work hard to keep your trusted AC running to the best of its ability with maintenance checks, and can stop by for repairs whenever they’re required. In need of a new AC system? We’re here to help you keep cool no matter what, with air conditioning services in Washington.
Heating Services, Washington
When the cold Michigan winter approaches, our first thought turns to the comfort of our local families in Washington and beyond. We’re here to ensure you stay warm through the long winter months, with furnace cleanings, inspections, maintenance, repairs and installations. We even offer 24-hour emergency heating services.
Furnace and AC Installation
If you’d like to upgrade to a new air conditioner or furnace, Randazzo has you covered. As the largest certified Lennox dealer located near Washington Township, we can offer you high quality equipment with a great warranty, at the lowest cost around. We strive to be the best heating and cooling company near the Washington Township area!
Water Heater Repair Washington, MI
Your hot water heater is essential, and we don’t want any of our neighbors to go without. Our water heater repair services are affordable and professional. With many parts stored in our trucks, chances are, we may be able to complete your repair there and then.
Electrician, Washington MI
Our exceptional electricians are here to serve you, Washington families. Whether you need us to install an automatic standby generator or complete lighting, fan or circuit repairs, our trusted team is here for you. Led by out master electrician, our team can offer you efficient, affordable repairs and peace of mind.
Local, Family Owned Heating and Cooling Contractor
At Randazzo, we believe in the personal touch. Located just outside of Washington Township, Michigan, we’re a family-owned furnace and air conditioner service company. Everyone here at Randazzo, from the President to the Janitor, lives and works nearby. For quality service you can trust, go with the name you know: Randazzo.
Request Your Free Quote
We’re proud to be a local HVAC company, offering home services for your heating and air conditioning, water heater and electric. When you choose to work with Randazzo, you receive exceptional customer service from our skilled technicians.
Our headquarters, on Quadrate Drive in Macomb, is just a 15-minute drive from Washington, Michigan. We’re the friendly neighbor you can count on to make your comfort our priority.
Contact us today to request your free quote, and enjoy the peace of mind that comes with working with a fully insured, certified, professional and local team.
Recent Jobs and Reviews in Washington, MI
Job Locations and Reviews
Responded to urgent service call for 4-month-old furnace system located in basement. Performed diagnostic evaluation using wireless 4-port manifold and micron gauge to assess refrigerant levels, pressures, and system vacuum conditions. Completed necessary measurements and testing to verify proper system operation under both part and labor warranty coverage.
Completed on-site evaluation and provided comprehensive estimate for full HVAC system replacement of 20+ year old air conditioning unit and furnace. AC unit was depleted of refrigerant and no longer operational. Assessed existing equipment in mechanical room, including furnace with humidifier attachment and associated ductwork. Documented current system configuration and discussed replacement options with homeowner for both heating and cooling components based on previous technician's recommendation for complete system upgrade.
Responded to no cooling complaint on 7-year-old Lennox air conditioning system. Upon arrival, confirmed unit was running but not adequately cooling the residence. Performed complete system diagnostics using calibrated manifold gauges and digital testing equipment. Measured operating pressures and temperatures, recording suction pressure of 72 PSI with superheat readings and discharge pressure of 1359 PSI at outdoor ambient conditions. Temperature readings indicated discharge line temperature of 141°F. Inspection of outdoor condensing unit revealed restricted airflow through condenser coil due to accumulated dirt, debris, and biological growth on fins. Noted algae/moss buildup on concrete pad and leaves around unit base indicating maintenance neglect. Condenser coil showed moderate dirt accumulation affecting heat rejection capacity. System analysis confirmed inadequate heat transfer at condenser resulting in elevated head pressures and reduced cooling efficiency. Cleaned condenser c
Completed annual preventive maintenance on residential split system air conditioning unit. Performed comprehensive inspection of outdoor condenser unit including removal of access panels for internal component examination, verified proper operation of condenser fan motor, assessed refrigerant line connections, and inspected electrical connections and contactors. Unit found to be in good operating condition with no deficiencies noted.
Completed scheduled air handler coil maintenance on residential HVAC system. Accessed furnace unit in mechanical room, inspected internal components including gas valve, electrical connections, and safety devices. Verified proper operation of all wiring and controls. Serviced outdoor condensing unit, performed cleaning and maintenance procedures on coil surfaces and exterior panels. All components tested and confirmed operational upon completion.
Completed annual cooling maintenance on residential outdoor condensing unit. Performed comprehensive system inspection including electrical connections, refrigerant lines, condensate drainage, and fan operation. Unit found in good operating condition with all components functioning properly. Cleaned condenser pad of debris and organic growth, verified proper airflow through louvers, and confirmed secure mounting of disconnect box and line set connections.
Responded to no-cool call where AC unit failed to activate while furnace operated normally. Upon inspection, diagnosed electrical issue preventing compressor engagement and restored system to full operational status. Unit tested successfully with proper airflow and cooling cycle confirmed before departure.
Performed scheduled maintenance on outdoor Kohler residential generator unit, including complete tune-up service and oil change. Accessed engine compartment, replaced engine oil, inspected air filter housing and all fluid reservoirs, and verified proper operation of control panel indicator lights and safety systems. All mechanical components, electrical connections, and conduit installations were inspected and found to be in proper working condition upon completion.
Completed furnace-only installation of a 135,000 BTU high-efficiency unit in basement mechanical room. Installation included proper venting with PVC intake and exhaust piping, electrical and gas reconnection, and humidifier integration with existing ductwork. All mechanical and electrical permits obtained, system tested and operational upon completion.
Completed full HVAC system installation including a 70,000 BTU gas furnace and 2.5 ton air conditioning unit with rear discharge configuration. Obtained mechanical and electrical permits prior to installation, performed complete system hookup and reconnection of all components, verified proper airflow through existing ductwork and floor registers, and ensured all electrical connections and gas lines were properly secured. Processed utility rebate documentation for DTE and SEMCO Energy programs, and coordinated Michigan Saves financing paperwork through electronic signature system.
Completed annual cooling maintenance on Lennox outdoor condenser unit. Performed comprehensive system inspection, cleaned condenser coils, verified refrigerant levels, tested electrical connections, and confirmed proper operation of all components. Unit operating within manufacturer specifications with no issues identified.
Completed full installation of tankless water heater unit in basement mechanical room, including wall mounting, hot and cold water supply connections with copper piping, gas line reconnection, and proper venting system installation. Installed exterior PVC vent piping with appropriate termination cap and intake configuration through foundation wall per manufacturer specifications. All required mechanical permits were obtained prior to installation, system was pressure tested, and unit was commissioned to verify proper operation and safety controls.
Completed furnace-only installation of 70,000 BTU unit with humidifier reconnection. Obtained mechanical and electrical permits prior to installation, performed all required electrical connections and ductwork integration, and verified proper system operation upon completion.
Completed routine air conditioning maintenance on Lennox condensing unit, including refrigerant and coil inspection. Performed standard RAC (refrigerant, amps, capacitor) diagnostics and pull visit to ensure system is operating within manufacturer specifications for the upcoming cooling season.
Completed annual cooling maintenance on residential outdoor condensing unit. Performed comprehensive system inspection, verified proper operation of compressor and condenser fan motor, checked refrigerant levels and electrical connections, and cleared minor debris accumulation from surrounding area and unit base.
Performed comprehensive water heater assessment in basement utility area for existing Bradford White Defender Safety System unit that was operational but experiencing performance issues. Evaluated current installation configuration including copper supply piping, pressure relief valve, expansion tank mounted on top of unit, shut-off valves, and venting system to determine replacement specifications. Documented existing natural draft or power vent setup, photographed current equipment layout including proximity to HVAC system and available clearances, and provided estimate for new water heater installation to restore optimal hot water delivery and system efficiency.
Completed annual cooling maintenance on residential split system air conditioning units. Performed comprehensive service on 2-5 ton rooftop/outdoor condenser units including spot cleaning of condenser coils, replacement of air filters, and installation of new humidifier pad. Conducted refrigerant pressure checks using manifold gauges to verify proper system charge and operation. Inspected electrical connections, tested system controls, and confirmed adequate airflow through all components. All equipment operating within manufacturer specifications upon completion of maintenance procedures.
Completed routine preventive maintenance on a 10-year-old Linux brand air conditioning system. Performed comprehensive inspection of outdoor condenser unit, including visual assessment of cabinet condition, refrigerant line connections, and mounting pad stability. Cleaned condenser coils and removed debris from unit exterior. Checked electrical connections and verified proper component operation. Inspected condensate drainage system and confirmed adequate airflow clearance around unit. System operating within normal parameters with no deficiencies noted at time of service.
Performed annual cooling maintenance on outdoor condensing units. Removed and cleaned side panels and protective grilles, inspected refrigerant lines and electrical connections, and conducted diagnostic testing using digital meters to verify system performance. All components were reassembled and units were left in proper operating condition.
Completed spring AC tune-up on 6-year-old Lennox condensing unit. Performed comprehensive maintenance including inspection of all components, cleaning of condenser coils with accumulated debris and organic matter, checked refrigerant levels, tested electrical connections, and verified proper system operation. Unit was found in working condition with normal seasonal buildup on exterior fins; cleaned and restored to optimal performance specifications.