Welcome, New Baltimore neighbors, we’re proud to serve you! Randazzo is your trusted, insured and certified team working on HVAC, heating and cooling in New Baltimore, MI.
If you live in or near New Baltimore, it’s likely you’ve heard our name. We have been privileged to serve residents of this area since 1988, and have had the opportunity to work with many of our neighbors. In fact, your coastal community and all its history are just a 15-20 minute drive from our Macomb headquarters, on Quadrate Drive. We’re conveniently located to serve you, with HVAC maintenance, repair and installation as well as 24-hour emergency services.
HVAC Contractor Serving New Baltimore
As a reputable, licensed and insured HVAC contractor, we are experts in heating, ventilation and air conditioning. We ensure your home stays warm all winter long, even when the lakefront winds feel cold and icy. With AC maintenance and repair, we can also help you stay cool, calm and collected in an air-conditioned home, throughout the hot summer months. Year round, we can improve the air quality in your home, to sooth your allergies. At a glance, our services include:
- Furnace and AC cleanings, inspections and maintenance.
- Heating and air conditioning repairs.
- Furnace and AC replacements and installations.
We’re also Michigan’s largest award-winning Lennox Premier Dealer. We know the ins and outs of Lennox products, and can help you choose the right equipment for your home and lifestyle. We also have vast experience working on a wide range of HVAC equipment from top brands, and can repair your current heating and cooling system.
Water Heater Repair in New Baltimore
Access to hot water is essential, and no-one should be without the ability to wash their dishes or enjoy a hot shower at the end of the day.
We maintain, repair and install electric, solar, propane, and natural gas water heaters, recirculation systems, heat pumps, as well as high efficiency tank and tankless hot water heaters.
Electrician, New Baltimore
If you’re looking for an electrician in New Baltimore, go with the name you know, and choose Randazzo. Led by our master electrician, all our work meets their impeccably high standards. Our team is available to complete the following services and more:
- Automatic standby generator installations
- Panel upgrades
- Circuit upgrades and repair
Contact Us for Heating and Cooling in New Baltimore, MI
In need of a maintenance check, repair or new HVAC system? Contact us today and receive a free quote from our team. If you don’t need us just yet, bookmark this page or take down our number, so you know where to turn when an urgent issue arises.
We can’t wait to meet you and visit your home by Lake St. Clair’s Anchor Bay. Thank you for taking the time to learn more about our team!
Recent Jobs and Reviews in New Baltimore, MI
Job Locations and Reviews
Completed annual heating maintenance on residential furnace system. Performed comprehensive inspection of all internal components including blower motor assembly, electrical connections, gas valve operation, and control board functionality. Replaced air filter and conducted safety checks on venting system, verified proper operation of all mechanical and electrical systems, and confirmed unit is operating within manufacturer specifications.
Completed routine air conditioning maintenance on residential outdoor condenser unit. Performed comprehensive AC tune-up including visual inspection of unit exterior, cabinet, and fan grille assembly. Connected manifold gauges to service ports and verified refrigerant pressures and system charge levels. Inspected electrical disconnect, conduit connections, and refrigerant line sets along brick wall mounting. Evaluated condenser coil condition through louvers, noting normal outdoor weathering and minor surface accumulation. Confirmed fan motor operation and proper airflow through top-mounted grille. Tested system performance and verified unit operating within manufacturer specifications. All components functioning properly with no deficiencies noted requiring immediate attention.
Completed comprehensive full system estimate for residential property with 16-year-old furnace and no existing air conditioning. Assessed basement mechanical room containing current heating equipment, water heater, and existing ductwork infrastructure running through floor joists and crawl space areas. Evaluated system capacity requirements and ductwork compatibility for new air conditioning installation, while also providing replacement options for aging furnace to take advantage of available promotional offerings. Documented existing HVAC infrastructure including metal ductwork configuration, equipment placement, and spatial considerations for optimal system installation.
Conducted comprehensive site assessment for Generac generator installation at residential property with no existing backup power system. Evaluated electrical panel capacity and available breaker positions, documented gas line accessibility from water heater location, and photographed mechanical room layout to determine optimal generator placement and connection points for future installation.
Completed comprehensive ComfortGuard preventive maintenance service on residential split-system air conditioning unit. Performed full system inspection of outdoor condenser unit, verified proper operation of compressor and condenser fan motor, cleaned condenser coils, checked refrigerant line insulation integrity, and confirmed electrical disconnect box functionality. All components found operating within normal parameters with no deficiencies noted.
Completed preventive maintenance and AC tune-up on two Lennox systems (4-year and 2-year units). Performed comprehensive inspection of outdoor condenser units, including cleaning of heavily soiled front panels and coils that had accumulated significant dirt, dust, and debris. Verified proper operation of fan assemblies, motor components, and refrigerant lines. All systems tested and confirmed operational with no issues found.
Performed scheduled air conditioning maintenance on residential condenser unit. Conducted system diagnostics using digital multimeter, measured operational parameters, and connected manifold gauge set to verify refrigerant pressures and system performance. Unit operating within normal specifications upon completion of preventive maintenance inspection.
Completed comprehensive assessment for full HVAC system replacement on 26-year-old equipment including natural gas furnace located in basement mechanical room and outdoor air conditioning condenser unit positioned on concrete pad in backyard. Both units currently operational but at end of serviceable life expectancy. Provided estimate for complete system replacement including new furnace with ductwork connections and matching condenser unit to improve efficiency and reliability.
Completed annual cooling maintenance on outdoor condensing unit. Performed comprehensive system inspection, measured operating temperatures and pressures, cleaned condenser coil fins of accumulated debris and dust, verified proper airflow through top discharge grille, and confirmed electrical disconnect functionality. Unit operating within normal parameters upon completion of preventive maintenance service.
Completed routine annual maintenance on a 10-year-old residential central air conditioning system. Performed comprehensive AC tune-up including inspection of outdoor condenser unit, verified proper operation of compressor and condenser fan motor, checked refrigerant pressures and temperatures, cleaned condenser coils, inspected electrical connections and contactors, and verified proper condensate drainage through PVC discharge line. System operating within normal parameters with no deficiencies noted at time of service.
Completed installation of 2-ton air conditioning system with evaporator coil on left-side configuration. Obtained mechanical and electrical permits prior to installation, then performed full system installation including refrigerant line connections, electrical reconnection, condensate drainage integration with existing PVC plumbing infrastructure, and ductwork connections to HVAC distribution system. System tested and operational upon completion, with utility rebate documentation collected for processing.
Completed annual cooling maintenance on Bryant outdoor condensing unit. Performed system inspection and operational testing. Customer requires replacement filters and evaporative cooler pads at next service interval.
Performed routine Air Care Maintenance on outdoor condensing unit that exhibited heavy accumulation of dirt, dust, and environmental debris on exterior panels and internal mesh screens. Cleaned condenser coils and air intake screens which were significantly clogged with grayish-brown material that was restricting proper airflow and reducing system efficiency. Unit was restored to optimal operating condition and all components inspected for proper function.
Completed complimentary annual heating maintenance through Air Care Membership on furnace system. Performed comprehensive tune-up inspection of all internal components including blower motor assembly, electrical connections, and control module. Verified proper operation of all mechanical and electrical systems, inspected wiring connections throughout unit, and documented equipment specifications and current condition with photographs. No issues identified; system operating within normal parameters.
Conducted comprehensive full system evaluation for HVAC replacement estimate on existing Bryant MS-80 furnace installation. Assessed current equipment condition, ductwork configuration, electrical panel compatibility, and mechanical room layout to provide customer with complete system replacement options for immediate installation.
Responded to no-heat call on 30+ year old furnace located on main floor. Upon arrival, performed diagnostic evaluation of gas-fired heating system. Inspected gas valve assembly, burner section, ignition system, and blower motor components. Identified issue preventing unit operation and completed necessary repairs to restore functionality. Verified proper ignition sequence, confirmed blue flame pattern at burners, and tested blower motor operation. Unit successfully cycled on and brought system back to normal operating condition with proper heat output.
Completed annual furnace maintenance and tune-up per membership agreement. Performed comprehensive inspection of all system components including gas valve assembly, blower motor, control boards, electrical connections, and safety controls. Verified proper operation of ignition system, heat exchanger integrity, and airflow. Inspected wiring throughout unit, checked all electrical connections for security, and confirmed control board functionality with heat sink cooling system operating correctly. All components found in proper working order with no deficiencies noted. System tested and left in full operational condition.
Performed routine Air Care Maintenance on residential air conditioning system. Inspected outdoor condensing unit, cleaned condenser coils, checked refrigerant levels, verified electrical connections at disconnect box, and tested system operation. Unit operating within normal parameters with no issues identified.
Completed scheduled AHC maintenance on heating and cooling system. Performed comprehensive inspection of air handler unit, including blower motor assembly, electrical connections, and control components. Verified proper amperage draw on blower motor using clamp meter, confirming system is operating within manufacturer specifications. All internal components found to be in good condition with no signs of wear or deterioration.
Completed annual summer AC maintenance inspection and tune-up on residential air conditioning system. Performed comprehensive system evaluation including condensate drain pan inspection, which revealed moderate accumulation of dust, debris, and mineral deposits around drain fitting and grommet. Documented existing conditions with photographic evidence showing surface deterioration and moisture staining on drain pan components, indicating need for future cleaning attention during next scheduled maintenance visit.