Welcome to Randazzo! We are the name to trust for heating and cooling in Novi, MI, Oakland County and the surrounding Metro Detroit area.
Our team provides HVAC services to Novi residents, as well as water heater repair and electrical services. Enjoy your Michigan home in comfort with a friendly service call from our professional, insured technicians.
We are proud to provide professional repair and installation to Novi residents, as well as our neighbors in Northville Twp., Plymouth, Canton and elsewhere across Metro Detroit.
Randazzo knows that sometimes, you need comprehensive, efficient work completed at a moment’s notice. We’re here for you and can provide services to keep your home comfortable in the cold winter and hot summer.
Our technicians will be there for you, arriving on time and full prepared for the job. Learn more about what we have to offer by reading below.
HVAC Repair & Installation Services in Novi, MI
You rely on the complete functionality of your heating and cooling units, year-round in Michigan. If your system is malfunctioning or it’s time for a new one, the HVAC specialists in Novi, MI, can help.
Talk to Randazzo about your heating and cooling needs. We’ll help you improve your efficiency and save money with a variety of service options. Looking for timely heating repair and AC repair in Novi, MI? Our insured technicians have extensive experience working with units from a wide variety of manufacturers, and we’ll diagnose any problem to get your units fixed ASAP.
If your energy bills are through the roof, we’ve got you covered. Not only will we help you lower your monthly payments, you’ll also have a better chance at prolonging your system life with our heating and air conditioning maintenance programs.
When it’s time to upgrade, Randazzo has the products you need. As Michigan’s largest award-winning Lennox Premier Dealer, we offer a full line of state-of-the-art air conditioning systems, furnaces, and more that can improve your indoor air quality.
Get in touch with the heating and cooling professionals in Novi, MI, today and ensure your comfort at home.
Water Heater Inspection & Repair in Novi, MI
Your hot water heater is a vital tool for your home. You use hot water to do the dishes, take a shower and launder your clothes. When this trusted piece of equipment stops working, professional assistance is often required. Randazzo offers Novi hot water heater inspection and repair services for a wide variety of units. Our team can repair or replace conventional, tankless, hybrid and other hot water heater types. Hot water is a necessity. Ensure you have reliable access to it in your home by booking a service visit for your unit today.
Electricians & Electrical Services in Novi
Losing power can make day-to-day tasks all too challenging. Stay out of the dark with a little help from your friends at Randazzo. Our team of skilled electricians are led by our master electrician and handle several types of electrical repairs and installations. Looking to have a standby generator installed? Is it time for new appliances that require panel or circuit upgrades? We can get it done. Look no further for a skilled electrician in Novi, Randazzo has your back.
Contact Randazzo Today
Randazzo believes in quality, efficiency, and outstanding customer service. For more than 30 years, we have provided Novi and the Metro Detroit area with HVAC, water heater repair and electrical services with these characteristics in mind. Our team looks forward to working with you to complete your next repair or installation. 586-336-1111 (toll free) today for more information, and contact us to request a free estimate.
Recent Jobs and Reviews in Novi, MI
Job Locations and Reviews
Responded to no-cooling complaint on residential air conditioning system. Upon arrival, found outdoor condensing unit producing buzzing sound with non-operational condenser fan motor. Inspected fan motor and capacitor assembly, identifying failed fan motor and weak dual run capacitor as root causes. Replaced defective condenser fan motor with OEM equivalent and installed new dual run capacitor to manufacturer specifications. Verified proper electrical connections, tested system operation, and confirmed condenser fan rotation and normal compressor function. Unit now cooling properly with no abnormal sounds. System returned to full operational status.
Responded to service call for 4-year-old furnace leaking water from the bottom. Upon inspection, identified condensate drainage issue causing water accumulation at base of unit. Cleared blocked condensate drain line and verified proper drainage flow. Inspected condensate pump operation and confirmed functional status. Checked heat exchanger and flue system for proper operation and no secondary leak sources. Tested furnace through complete heating cycle to ensure no further water leakage. Unit operating normally with no additional concerns noted. Equipment remains under parts and labor warranty.
Completed final ComfortGuard maintenance visit on dual outdoor AC condenser units. Performed comprehensive inspection of both condensing units, including evaluation of cooling fins which showed accumulation of dirt and debris, checked fan guards, assessed electrical connections, and verified proper operation of all components. Documented equipment condition with photographs showing units positioned on concrete pad with natural debris accumulation from surrounding vegetation and tree roots, confirming maintenance completion for this recurring service agreement.
Completed annual maintenance on dual Lennox outdoor condenser units. Removed and cleaned heavily soiled air filter panels that had significant dust and debris accumulation affecting airflow. Performed standard ACM inspection procedures, removed access panels for internal component access, and conducted necessary maintenance tasks. Both units were serviced and restored to proper operating condition.
Completed annual cooling maintenance on outdoor condensing unit. Unit exterior and condenser coil showed heavy accumulation of dirt, dust, and debris from extended environmental exposure. Cleaned condenser coil fins thoroughly to restore proper airflow and heat transfer efficiency. Removed debris buildup from unit exterior panels and surrounding base area. Inspected fan assembly and verified operational condition. System restored to optimal performance standards following maintenance procedures.
Performed routine preventative maintenance on residential central air conditioning system. Conducted comprehensive tune-up inspection including visual assessment of furnace unit, ductwork connections, condensate drainage system, and electrical control board components. Verified proper operation of all system controls and wiring connections. Adjusted air filter housing insertion point per customer request to improve accessibility. Confirmed unit warranty coverage status with customer. System operating within normal parameters with no deficiencies noted. Documented equipment condition through photographic records showing mechanical room installation and internal control panel assembly.
Completed routine spring air conditioning maintenance on a 10-year-old residential AC system. Performed comprehensive tune-up including inspection of indoor furnace unit, tested system pressures and temperatures using digital manifold gauges, and verified proper refrigerant levels and operating parameters. System found to be functioning properly with no deficiencies noted.
Completed comprehensive spring air conditioning maintenance tune-up on outdoor condenser unit. Performed thorough cleaning of condenser coils and fins which showed significant dirt and debris accumulation, inspected electrical connections and refrigerant levels, and verified proper system operation. Provided estimate for upgraded thermostat replacement per request and discussed air scrubber installation options with recommendations for improved indoor air quality.
Completed annual maintenance on a one-year-old central HVAC system including both forced air furnace and air conditioning components. Performed comprehensive AC tune-up, inspected blower motor assembly and electrical connections, verified proper operation of all system components, checked wiring harnesses and motor housing, and confirmed air filter condition. System found to be operating within normal parameters with no deficiencies noted.
Successfully installed a 17-gallon whole-home humidifier system integrated with the existing HVAC infrastructure. Installation included mounting the humidifier unit between floor joists, routing copper water supply lines with proper bracketing and securing methods, connecting to the ductwork system using metal flex duct with appropriate clamps, and completing all necessary electrical connections. All components were properly secured to structural framing members and tested for proper operation upon completion.
Completed annual heating maintenance and tune-up on furnace system with no reported issues. Performed comprehensive inspection of all internal components including blower assembly, motor, heat exchanger, electrical connections, and wiring harnesses. All components found to be operating within normal parameters, system tested and verified for proper operation.
Responded to no heat call on 6-year-old natural gas furnace experiencing intermittent operation. Upon arrival, conducted full system diagnostic including visual inspection of internal components and electrical connections. Accessed furnace cabinet and inspected pressure switch assembly, flame sensor, ignition system, and wiring harness. Identified loose wire connection at pressure switch terminal causing intermittent circuit interruption. Secured connection and verified proper seating of all electrical connectors. Performed amp draw testing on blower motor using digital clamp meter, confirming normal operating current within manufacturer specifications. Cycled system multiple times to verify consistent ignition sequence and proper heating operation. System now functioning normally with no further intermittent issues observed.
Completed second appointment of annual cooling maintenance service at two residential properties. Performed comprehensive inspection of outdoor condensing units, including visual assessment of cabinet condition, coil cleanliness, and electrical connections. Documented equipment condition with photos showing condenser with debris accumulation on mesh screening and open service panel revealing refrigerant lines, wiring, and internal components in operational status.
Performed annual cooling maintenance on outdoor condensing unit. Upon inspection, found heavy accumulation of dirt, dust, and debris on condenser coils and internal components. Removed front access panel and thoroughly cleaned condenser coil fins to restore proper airflow and heat transfer efficiency. Removed compacted grime and debris from interior surfaces. Verified unit operational status and cleared landscaping rock from concrete pad. System restored to optimal operating condition for cooling season.
Responded to service call for water heater with small drip in basement. Upon inspection, identified corroded copper piping at water heater connection point showing significant oxidation and mineral buildup. The 2017 water heater exhibited leakage at the inlet plumbing assembly where deteriorated copper pipe connected to brass fittings. Documented existing conditions showing compromised pipe integrity with visible surface degradation and discoloration throughout the affected copper sections. Equipment is not covered under parts or labor warranty.
Replaced defective exhaust pipe on HVAC system in basement utility area. System tested and verified proper venting operation upon completion, with homeowner's authorized representative present to approve repair work.
Completed complimentary annual furnace maintenance tune-up for Air Care Membership customer on a brand new furnace system. Performed comprehensive inspection of all internal components including gas valve assembly, electrical connections, blower motor housing, and control systems. All wiring connections, safety controls, and mechanical assemblies verified to be in proper working condition with no issues found.
Installed new thermal expansion tank on domestic water system. Mounted blue steel expansion tank horizontally to wall, connected to copper supply piping using compression fittings, and verified proper system pressurization upon completion.
Completed comprehensive assessment and provided replacement estimate for 30-year-old residential HVAC system including both furnace and air conditioning unit. Inspected existing beige sheet metal furnace cabinet located in basement utility area with connected ductwork, plenum transitions, and flexible duct runs, as well as exterior condensing unit positioned at foundation level near crawl space vents. Documented current system configuration, ductwork connections, copper refrigerant lines, and equipment accessibility for replacement planning within requested 30-day timeframe.
# HVAC Service Report - No Heat Call ## Service Summary Responded to no heat call on 10-year-old gas furnace that had completely stopped operating. Diagnosed and resolved issue, restoring heat to residence. ## Work Performed Upon arrival, performed visual inspection of furnace system and electrical components. Examined gas valve assembly, control board, and associated wiring connections. Verified proper voltage supply to unit and tested low-voltage control circuit functionality. Inspected condensate drain system including PVC drain lines and drain pan for blockages or water accumulation that could trigger safety switches. Checked flexible metallic conduit and junction box connections for secure electrical pathways. Evaluated blower motor assembly and associated wire harnesses for proper connections and operational status. Tested furnace ignition sequence and flame sensing components. Verified gas valve operation and proper gas flow to burner assembly. Examined control board LED d